Aerosol-to-Hydrosol Transfer Stages for use in bioaerosol sampling /
Single-Jet and Multi-Jet Aerosol to Hydrosol Transfer Stages (AHTS) with cutpoints of 2 and 0.8 []m AD, respectively, were designed and evaluated. Both devices operate at nominal air sampling flow rate of 1 L/min, 0.1% Tween®20, and 0.3 mL/min. collection liquid flow rate. Both systems have an ide...