MARC

Tag First Indicator Second Indicator Subfields
LEADER 00000cam a2200000 i 4500
001 in00005676413
005 20260121210952.2
006 m o d
007 cr cnu||||||||
008 220104t20192019vau fo 001 0 eng d
040 |a Q2U  |b eng  |e rda  |c Q2U  |d OCLCF  |d SHC  |d OCLCQ  |d OCLCO  |d OCLCQ  |d OCLCL  |d OCLCQ 
019 |a 1317425600 
020 |a 1523129425 
020 |a 9781523129423 
035 |a (OCoLC)1315856405  |z (OCoLC)1317425600 
050 4 |a K3242  |b .A525 2019 
082 0 4 |a 621.31922  |2 23 
049 |a TXAM 
100 1 |a Lines, Task Committee on Fiber-Reinforced Composite Structures for Overhead. 
245 1 0 |a Recommended Practice for Fiber-Reinforced Polymer Products for Overhead Utility Line Structures, Second Edition. 
246 3 |a Recommended Practice for Fiber-Reinforced Polymer Products for Overhead Utility Line Structures 
250 |a 2nd ed. 
264 1 |a Reston :  |b American Society of Civil Engineers,  |c 2019. 
264 4 |c ©2019. 
300 |a 1 online resource (227 pages). 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a Manuals and Reports on Engineering Practice Ser. ;  |v v.104 
505 0 |a Mop_104 _online.pdf -- MANUALS AND REPORTS ON ENGINEERING PRACTICE -- CONTENTS -- PREFACE -- 1. STRUCTURES AND APPLICATIONS -- 1.1 Introduction -- 1.2 When to Use FRP Composite Components -- 1.2.1 Where Traditional Materials Do Not Last as Long as They Should -- 1.2.2 Where Structure Installation Cost Is Higher Than Average -- 1.2.3 Where High-Performance Solutions Are Required -- 1.3 Structure Configurations -- 1.3.1 Cantilevered Structures -- 1.3.2 Framed Structures -- 1.3.3 Guyed Structures -- 1.3.4 Combined Structures -- 1.4 Applications -- 1.4.1 Transmission and Distribution Structures -- 1.4.2 Substation Structures -- 1.4.3 Lighting Supports, Highway Signs, and Traffic Signal Structures -- 1.4.4 Communication Structures -- 2. MATERIALS -- 2.1 Introduction -- 2.2 Material Composition -- 2.2.1 Thermosets and Thermoplastics -- 2.2.2 Thermoset Polymer Resins -- 2.2.3 Additives and Fillers -- 2.2.4 Fiber Reinforcement -- 2.3 Design Criteria for Material Selection -- 2.4 FRP Material and Process Characteristics -- 2.4.1 Material Characteristics -- 2.4.2 Manufacturing Processes -- 3. DESIGN CONSIDERATIONS -- 3.1 Introduction -- 3.2 Physical Considerations -- 3.3 Transportation -- 3.4 Connections -- 3.5 Guy Wire Connections -- 3.6 Guy Wire Anchors -- 3.7 Grounding -- 3.8 Climbing -- 3.8.1 Steps -- 3.8.2 Ladders -- 3.9 Aesthetic Considerations -- 3.10 Structural Loading -- 3.10.1 Introduction -- 3.10.2 Load Considerations for Overhead Distribution and Transmission Power Lines -- 3.10.3 Legislated (or Code) Loads -- 3.10.4 Meteorological Loads -- 3.10.5 Longitudinal Loads -- 3.10.6 Construction and Maintenance Loads -- 3.10.7 Structure-Strength Equivalency -- 3.10.8 Deflection and Serviceability Equivalency -- 3.11 Durability -- 3.12 Foundations -- 3.12.1 Geotechnical Analysis -- 3.12.2 Foundation Design -- 3.13 Service Life -- 3.14 Strength. 
505 8 |a 3.15 Electrical Performance -- 3.16 Environment -- 3.17 Life-Cycle Evaluations -- 3.18 Joints -- 3.18.1 Slip Joints -- 3.18.2 Flange and Other Mechanical Joints -- 4. DESIGN CRITERIA -- 4.1 Introduction -- 4.2 Designing with FRP Products -- 4.3 Poles -- 4.3.1 Mechanical Properties -- 4.3.2 Bending Strength -- 4.3.3 Local Buckling Strength -- 4.3.4 Axial Strength -- 4.3.5 Pull-Through Strength -- 4.3.6 Hoop Strength -- 4.3.7 Torsional Strength -- 4.3.8 Fatigue Strength -- 4.3.9 Deflection -- 4.4 Crossarms -- 4.4.1 Mechanical Properties -- 4.4.2 Bending and Shear Strength -- 4.4.3 Deflections -- 5. SUGGESTED GUIDELINES FOR PERFORMANCE-BASED TESTS -- 5.1 Introduction -- 5.2 Recommended Mechanical Tests -- 5.2.1 Static Bending (Horizontal Loading) Test -- 5.2.2 Bolt Torque Test -- 5.2.3 Bolt Pull-Through Test -- 5.2.4 Direct Load Shear Test -- 5.2.5 Field Drillability Test -- 5.2.6 Step Bolt Compatibility Test -- 5.3 Optional Mechanical Tests -- 5.3.1 Torsional Load Test -- 5.3.2 Fatigue Tests -- 5.3.3 Permanent Deflection Tests -- 5.3.4 Slip Joint Tests -- 5.3.5 Column Buckling Tests -- 5.4 Laminate Durability and Integrity Tests -- 5.4.1 Ultraviolet (UV) Radiation Tests -- 5.4.2 Hydrophobicity Tests -- 5.4.3 Water Absorption Tests -- 5.4.4 Leaching Tests -- 5.4.5 Fire Tests -- 5.4.6 Coating Tests -- 5.4.7 Impact Testing -- 5.5 Electrical Tests -- 6. QUALITY ASSURANCE -- 6.1 Introduction -- 6.2 Design and Drawings -- 6.3 Material Combination, Manufacturing Equipment, and Process -- 6.4 Material Standards Conformance -- 6.5 Tolerances -- 6.6 Surface Coatings -- 6.7 Inspection During Manufacture -- 6.8 Receiving and Shipping -- 6.9 Rejection -- 6.10 Full-Scale Structure Testing -- 6.11 Installation, Inspection, and Maintenance -- 7. ASSEMBLY AND ERECTION -- 7.1 Introduction -- 7.2 FRP Poles -- 7.2.1 Storage -- 7.2.2 Handling -- 7.2.3 Transportation. 
505 8 |a 7.2.4 Assembly -- 7.2.5 Joint Assembly -- 7.2.6 Framing -- 7.2.7 Field Drilling -- 7.2.8 Cutting -- 7.2.9 Erection -- 7.2.10 Climbing -- 7.3 FRP Foundations -- 8. ATTACHMENTS -- 8.1 Introduction -- 8.2 Attachments -- 8.2.1 Attachment Components -- 8.2.2 Guying/Tension Attachments -- 8.2.3 FRP Guy Wire Anchor -- 8.2.4 Bearing Plate -- 8.2.5 Strap-Style Pole Band -- 8.2.6 Link-Style Pole Band -- 8.2.7 Washers -- 8.2.8 Climbing Hardware -- 8.2.9 Shield Wire Supports -- 8.2.10 Post Insulator Gain Bases (Mounting Brackets) -- 8.2.11 Base Plates -- 8.2.12 Conical Top Cap -- 8.2.13 Flat Top Cap -- 8.2.14 Rock Mounts -- 8.2.15 Pole ID Tag -- 8.2.16 Bonding/Grounding Hardware -- 8.2.17 Crossarm Mounting Brackets -- 8.3 Attachment Hardware Assemblies -- 9. IN-SERVICE CONSIDERATIONS -- 9.1 Introduction -- 9.2 Factors Influencing Performance of FRP Materials -- 9.2.1 Environment -- 9.2.2 Mechanical Fatigue -- 9.2.3 Electrical Stress and Leakage Current -- 9.3 Field Inspection -- 9.3.1 Visual Inspection -- 9.3.2 Tap Test -- 9.3.3 Other Tests -- 9.4 Repair Options -- 9.4.1 Take No Action -- 9.4.2 Repair in the Field -- 9.4.3 Component Replacement -- Appendix A. GLOSSARY -- Appendix B. BIBLIOGRAPHY -- Appendix C. SUGGESTED MANUFACTURING TOLERANCES -- Appendix D. LOADING REQUIREMENTS FOR FRC POLES UTILIZED IN OTHER THAN UTILITY LINE APPLICATIONS -- Appendix E. COMMENTARY -- INDEX. 
520 3 |a Prepared by the Task Committee on Fiber-Reinforced Polymer Products for Overhead Utility Line Structures of the Structural Engineering Institute of the American Society of Civil Engineers.Recommended Practice for Fiber-Reinforced Polymer Products for Overhead Utility Line Structures, MOP 104, Second Edition, details best practices for the use of fiber-reinforced polymer (FRP) composite poles and crossarms in resilient conductor support applications. With continued advancements and innovations in the composite industry in the 16 years since the first edition was published, this new edition updates and expands on nearly every aspect of FRP pole and crossarm testing, design considerations, installation, and asset management, providing the line designer with another tool in the line design tool box in addition to the traditional materials of wood, steel, and concrete. MOP 104, Second Edition, provides recommendations and suggested guidelines for performance-based tests for all FRP components, discusses factors that could affect the performance of FRP poles after installation, suggests field inspection methods, and provides basic maintenance and field repair techniques. Notable updates includeRecommendations on when to utilize FRP products; An in-depth review of serviceability equivalency (id est, deflection) and strength equivalency for optimized FRP composite pole selection;Material industry best practice hardware solutions for FRP structures for a range of overhead line framings;Comprehensive installation review including foundation options; andField inspection recommendations, including fiber bloom examples, and potential maintenance requirements.This manual of practice will be valuable to overhead line asset owners and engineers involved in utility, electrical, and structural engineering. 
588 |a Print version record. 
650 0 |a Electric lines  |x Poles and towers  |x Design and construction. 
650 0 |a Electric lines  |x Poles and towers  |x x Materials. 
650 0 |a Fiber-reinforced plastics. 
650 6 |a Matières plastiques renforcées avec des fibres. 
650 7 |a Electric lines  |x Poles and towers  |x Design and construction  |2 fast 
650 7 |a Fiber-reinforced plastics  |2 fast 
653 0 |a Fiber reinforced polymer 
653 0 |a Utilities 
653 0 |a Synthetic materials 
653 0 |a Structural engineering 
653 0 |a Composite structures 
653 0 |a Power transmission poles 
653 0 |a Composite materials 
653 0 |a Asset management 
655 7 |a Electronic books.  |2 local 
710 2 |a Knovel (Firm) 
710 2 |a American Society of Civil Engineers. 
776 1 |z 0784415447 
830 0 |a Manuals and Reports on Engineering Practice Ser. 
856 4 0 |u http://proxy.library.tamu.edu/login?url=https://app.knovel.com/hotlink/toc/id:kpRPFRPP01/recommended-practice-for?kpromoter=marc  |z Connect to the full text of this electronic book  |t 0 
936 |a BATCHLOAD 
955 |a Knovel ebooks 
994 |a 92  |b TXA 
999 f f |i e52fe8bb-bd32-47d2-bc09-1bf854ded8fc  |s 67fbec3b-702e-4acb-b3e6-9179d60ba8be  |t 0 
952 f f |a Texas A&M University  |b College Station  |c Electronic Resources  |s www_evans  |d Available Online  |t 0  |e K3242 .A525 2019  |h Library of Congress classification 
998 f f |a K3242 .A525 2019  |t 0  |l Available Online