Miswiring in a Westinghouse rod control system.
| Format: | Government Document eBook |
|---|---|
| Language: | English |
| Published: |
Washington, D.C. :
United States Nuclear Regulatory Commission, Office of Inspection and Enforcement,
1987.
|
| Series: | Information notice ;
no. 87-05. |
| Subjects: | |
| Online Access: | https://purl.fdlp.gov/GPO/gpo148949 |
Similar Items
Reactor trip breaker, Westinghouse model DS-416, failed to open on manual initiation from the control room.
Published: (1987)
Published: (1987)
Electrical wire insulation degradation caused failure in a safety-related motor control center.
Published: (1991)
Published: (1991)
Potential failures of Westinghouse Electric Corporation type SA-1 differential relays.
Published: (1983)
Published: (1983)
Electrical component failure due to degradation of polyvinyl chloride wire insulation.
Published: (1994)
Published: (1994)
Component failures caused by elevated DC control voltage.
Published: (1983)
Published: (1983)
Problems with Westinghouse DS-206 and DSL-206 type circuit breakers.
Published: (1992)
Published: (1992)
Fuse problems with Westinghouse 7300 printed circuit cards.
Published: (1993)
Published: (1993)
Potential loss of safe shutdown equipment due to premature silicon controlled rectifier failure.
Published: (1988)
Published: (1988)
Potential deficiencies in environmental qualification of Limitorque motor valve operator wiring.
Published: (1986)
Published: (1986)
Recent Identified problems with Limitorque motor operators.
Published: (1986)
Published: (1986)
Problems associated with testing, tuning, or resetting of digital control systems while at power.
Published: (1996)
Published: (1996)
Potential deficiency in improperly rated field wiring to solenoid valves.
Published: (1984)
Published: (1984)
Failure of undervoltage trip attachment on Westinghouse Model DE-50 reactor trip breaker.
Published: (1993)
Published: (1993)
Failures of AGASTAT CR 0095 relay sockets.
Published: (1982)
Published: (1982)
Potential deficiency of certain AGASTAT E-7000 series time-delay relays.
Published: (1982)
Published: (1982)
Westinghouse type DS circuit breakers, potential failure of electric closing feature because of broken spring release latch lever.
Published: (1985)
Published: (1985)
Degraded DC system at Palisades.
Published: (1981)
Published: (1981)
Control rod drive system malfunctions.
Published: (1981)
Published: (1981)
Potential deficiency of certain class 1E instrumentation and control cables.
Published: (1993)
Published: (1993)
Maintenance deficiency associated with General Electric horizontal custom 8000 induction motors.
Published: (1991)
Published: (1991)
Incorrect configuration of breaker operating springs in General Electric AK-Series metal-clad circuit breakers.
Published: (1991)
Published: (1991)
Failure of ITE model K-600 circuit breaker.
Published: (1981)
Published: (1981)
Sheared pinion gear-to-shaft keys in Limitorque motor actuators.
Published: (1990)
Published: (1990)
Defective motor shaft keys in Limitorque motor actuators.
Published: (1988)
Published: (1988)
Potential design deficiency in motor-operated valve control circuitry.
Published: (2013)
Published: (2013)
Thermal sleeve flange wear leads to stuck control rod at foreign nuclear plant.
Published: (2018)
Published: (2018)
Cracked insulators in ASL dry type transformers manufactured by Westinghouse Electric Corporation.
Published: (1992)
Published: (1992)
Insulation breakdown of silicone rubber-insulated single conductor cables during high potential testing.
Published: (1987)
Published: (1987)
Mechanical failure of indicating-type fuses.
Published: (1987)
Published: (1987)
Deficiencies in ferro-resonant transformers.
Published: (1984)
Published: (1984)
Failures of the undervoltage, trip function of reactor trip system breakers.
Published: (1983)
Published: (1983)
Failures of Class 1E safety-related switchgear circuit breakers to close on demand.
Published: (1983)
Published: (1983)
High energy arcing faults in electrical equipment containing aluminum components.
Published: (2017)
Published: (2017)
Station battery problems.
Published: (1985)
Published: (1985)
Potential problems in identifying causes of emergency diesel generator malfunctions.
Published: (1991)
Published: (1991)
Degradation of Westinghouse ARD relays.
Published: (1988)
Published: (1988)
Environmental qualification of Litton-Veam CIR series electrical connectors.
Published: (1989)
Published: (1989)
Loss of offsite power caused by problems in fiber optics systems.
Published: (1986)
Published: (1986)
Loss of vital AC power with subsequent reactor coolant system heat-up.
Published: (1990)
Published: (1990)
Reactor trip breaker malfunctions (undervoltage trip devices on GE Type AK-2-25 breakers).
Published: (1983)
Published: (1983)