Failure of a General Electric type AK-2-25 reactor trip breaker.
| Format: | Government Document eBook |
|---|---|
| Language: | English |
| Published: |
Washington, D.C. :
United States Nuclear Regulatory Commission, Office of Inspection and Enforcement,
1985.
|
| Series: | Information notice ;
85-58. |
| Subjects: | |
| Online Access: | https://purl.fdlp.gov/GPO/gpo147205 |
Similar Items
Reactor trip breaker malfunctions (undervoltage trip devices on GE Type AK-2-25 breakers).
Published: (1983)
Published: (1983)
Potential failure of General Electric Magne-Blast circuit breakers and AK circuit breakers.
Published: (1990)
Published: (1990)
Failure of circuit breaker following installation of Amptector direct trip attachment.
Published: (1988)
Published: (1988)
Failure of undervoltage trip attachment on General Electric circuit breakers.
Published: (1988)
Published: (1988)
Failure of Westinghouse W-2-type circuit breaker cell switches.
Published: (1987)
Published: (1987)
Failure of undervoltage trip attachment on Westinghouse Model DE-50 reactor trip breaker.
Published: (1993)
Published: (1993)
Incorrect configuration of breaker operating springs in General Electric AK-Series metal-clad circuit breakers.
Published: (1991)
Published: (1991)
Reactor trip breakers and surveillance testing of auxiliary circuits.
Published: (1997)
Published: (1997)
Potential problems with metal-clad circuit breakers, General Electric type AK-2-25.
Published: (1987)
Published: (1987)
General Electric Magne-Blast circuit breaker problems.
Published: (1984)
Published: (1984)
Failures of General Electric Magne-Blast circuit breakers.
Published: (1996)
Published: (1996)
Mechanical interference with thermal trip function in GE molded-case circuit breakers.
Published: (1990)
Published: (1990)
Circuit breaker failures due to loose charging spring motor mounting.
Published: (1988)
Published: (1988)
Potential problems in Westinghouse molded case circuit breakers equipped with a shunt trip.
Published: (1986)
Published: (1986)
Potential faliure of General Electric Magne-Blast circuit breaker subcomponents.
Published: (1997)
Published: (1997)
Cracked and broken piston rods in Brown Bovery electric type 5HK breakers.
Published: (1983)
Published: (1983)
Time/current trip curve discrepancy of ITE/Siemens-Allis molded case circuit breaker.
Published: (1985)
Published: (1985)
Operating experience regarding electrical circuit breakers.
Published: (2007)
Published: (2007)
Potential breaker miscoordination caused by instantaneous trip circuitry.
Published: (1992)
Published: (1992)
Failures of General Electric magne-blast circuit breakers to latch closed.
Published: (1994)
Published: (1994)
Mechanical binding of spring release device in Westinghouse type DS-416 circuit breakers.
Published: (1988)
Published: (1988)
Circuit breaker position verification.
Published: (1984)
Published: (1984)
Remote trip function failures in General Electric f-frame molded-case circuit breakers.
Published: (1992)
Published: (1992)
Failures of certain Brown Boveri electric circuit breakers.
Published: (1987)
Published: (1987)
Failure of ITE model K-600 circuit breaker.
Published: (1981)
Published: (1981)
Potential failure of ASEA Brown Boveri circuit breakers during seismic event.
Published: (1989)
Published: (1989)
Licensee report of defective refurbished circuit breakers.
Published: (1988)
Published: (1988)
Spurious tripping of low-voltage power circuit breakers with GE RMS-9 digital trip units.
Published: (1993)
Published: (1993)
Problems with levering-in devices in Westinghouse circuit breakers.
Published: (1996)
Published: (1996)
Reactor trip breaker, Westinghouse model DS-416, failed to open on manual initiation from the control room.
Published: (1987)
Published: (1987)
Westinghouse type DS circuit breakers, potential failure of electric closing feature because of broken spring release latch lever.
Published: (1985)
Published: (1985)
Changes in performance characteristics of molded-case circuit breakers.
Published: (1989)
Published: (1989)
Reactor trips caused by breaker testing with fault protection bypassed.
Published: (1993)
Published: (1993)
Hardened or contaminated lubricants cause metal-clad circuit breaker failures.
Published: (1995)
Published: (1995)
inadequate work practices resulted in faulted circuit breaker connections.
Published: (2016)
Published: (2016)
Inadequate verfication of overcurrent trip setpoints in metal-clad, low-voltage circuit breakers.
Published: (1998)
Published: (1998)
Potential binding of Schneider Electric/Square-D Masterpact NT and NW 480-Vac circuit breaker anti-pump feature.
Published: (2017)
Published: (2017)
Tripping of Klockner-Moeller molded-case circuit breakers due to support lever failure.
Published: (1993)
Published: (1993)
Disabling of diesel generator output circuit breakers by anti-pump circuitry.
Published: (1988)
Published: (1988)
Status indication of control power for circuit breakers used In safety-related applications.
Published: (1991)
Published: (1991)