Main steam line break effect on environmental qualification of equipment.
| Format: | Government Document eBook |
|---|---|
| Language: | English |
| Published: |
Washington, D.C. :
United States Nuclear Regulatory Commission, Office of Inspection and Enforcement,
1984.
|
| Series: | NRC information notice ;
84-90. |
| Subjects: | |
| Online Access: | https://purl.fdlp.gov/GPO/gpo146725 |
Similar Items
Locking devices inadequately installed on main steam isolation valves.
Published: (1981)
Published: (1981)
Main steam isolation valve (MSIV) leakage.
Published: (1982)
Published: (1982)
Potential design deficiency in motor-operated valve control circuitry.
Published: (2013)
Published: (2013)
Potential deficiencies in environmental qualification of Limitorque motor valve operator wiring.
Published: (1986)
Published: (1986)
Main steam safety valve failures caused by failed cotter pins.
Published: (1984)
Published: (1984)
Vibration-induced valve failures.
Published: (1983)
Published: (1983)
Failures in turbine exhaust lines.
Published: (1982)
Published: (1982)
Failure of three check valves on high pressure injection lines to pass flow.
Published: (1982)
Published: (1982)
Failure of motor-operated valve electric power train due to sheared or dislodged motor pinion gear key.
Published: (1994)
Published: (1994)
Maintenance deficiency associated with solenoid-operated valves.
Published: (1990)
Published: (1990)
Safety injection pipe failure.
Published: (1988)
Published: (1988)
Tube leakage due to a fabrication flaw in a replacement steam generator.
Published: (2004)
Published: (2004)
Main steam isolation valve closure logic.
Published: (1985)
Published: (1985)
Common mode failure of main steam isolation nonreturn check valves.
Published: (1983)
Published: (1983)
Failures of Rockwell International globe valves.
Published: (1984)
Published: (1984)
Check valve failures.
Published: (1981)
Published: (1981)
Failure of anti-rotation keys in motor-operated valves manufactured by Velan.
Published: (1993)
Published: (1993)
Weakness in emergency operating procedures found as result of steam generator tube rupture.
Published: (1993)
Published: (1993)
Failure of safety injection valves to operate against differential pressure.
Published: (1981)
Published: (1981)
Environmental qualification testing experience.
Published: (1983)
Published: (1983)
Environmental qualification of safety-related equipment.
Published: (1980)
Published: (1980)
Results of open testing for the program to assess the reliability of emerging nondestructive techniques /
by: Meyer, R. M., et al.
Published: (2017)
by: Meyer, R. M., et al.
Published: (2017)
Recent NRC-sponsored testing of motor-operated valves.
Published: (1989)
Published: (1989)
Results of NRC-sponsored testing of motor-operated valves.
Published: (1990)
Published: (1990)
Defective RHR replacement piping.
Published: (1984)
Published: (1984)
Equipment qualification testing experience.
Published: (1981)
Published: (1981)
Potential failure of Westinghouse steam generator tube mechanical plugs.
Published: (1989)
Published: (1989)
Feedwater line break.
Published: (1986)
Published: (1986)
Equipment environmental qualification testing experience - updating of test summaries previously published in 81-29.
Published: (1982)
Published: (1982)
Environmental qualification of safety-related electrical equipment.
Published: (1982)
Published: (1982)
Possible flaws in certain piping systems fabricated by Associated Piping and Engineering.
Published: (1991)
Published: (1991)
Failures of Hiller actuators upon gradual loss of air pressure.
Published: (1982)
Published: (1982)
Deficiency in design modification to address faliures of Hiller actuators upon a gradual loss of air pressure.
Published: (1992)
Published: (1992)
Main steam isolation valve failure to close on demand because of inadequate maintenance and testing.
Published: (1994)
Published: (1994)
Orders on environmental qualification of safety related electrical equipment.
Published: (1980)
Published: (1980)
Deficiencies in equipment qualification testing and certification process.
Published: (1985)
Published: (1985)
Failure of condensate piping because of erosion-corrosion at a flow-straightening device.
Published: (1995)
Published: (1995)
RCIC and HPCI turbine exhaust check valve failures.
Published: (1982)
Published: (1982)
Potential failures of auxiliary steam piping and the possible effects on the operability of vital equipment.
Published: (1990)
Published: (1990)
Final report on advanced nondestructive evaluation for steam generator tubing for the Second International Steam Generator Tube Integrity Program /
Published: (2003)
Published: (2003)