Development of an electrical resistivity probe for void-fraction measurements in air-water flow /

Bibliographic Details
Main Author: Nassos, George P.
Corporate Authors: Associated Midwest Universities, Argonne National Laboratory. Reactor Engineering Division
Format: Government Document Book
Language:English
Published: Argonne, Ill. : Argonne National Laboratory, 1963.
Series:ANL (Series) ; 6738.
Subjects:
Description
Abstract:Work was done on the adaptation of an electrical probe, developed by Neal for the measurement of local void fractions in mercury-nitrogen flow, to air- water flow. The adaptation is more difficult because of wetting of the probe by water. Various probe shapes and filming agents were employed without great success. Some improvement was obtained by means of a separate triggering circuit, but the calculated void fraction was still somewhat low compared with that measured by the gamma-ray-attenuation technique. Presumably, this is due to a finite response time of the probe, associated with the wetting of the tip; hence, further development of this technique is necessary.
Item Description:"Engineering and Equipment" -title page.
"(TID-4500, 22nd edition) ; AEC Research and Development Report" -title page.
Physical Description:37 pages : illustrations ; 28 cm.
Bibliography:Includes bibliographical references (page 35).