Maximum temperature calculation and operational characteristics of fuel follower control rods for the AFRRI TRIGA reactor facility /

Operational requirements of the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor necessitate the implementation of fuel follower control rods (FFCR's). This technical report discusses the operational and safety aspects of FFCR installation. Thermal hydraulic analysis shows tha...

Full description

Bibliographic Details
Main Author: Forsbacka, M.
Corporate Author: Armed Forces Radiobiology Research Institute (U.S.)
Other Authors: Moore, M.
Format: Government Document eBook
Language:English
Published: Bethesda, Md. : Defense Nuclear Agency, Armed Forces Radiobiology Research Institute, [1991]
Series:AFRRI technical report ; TR 91-1.
Subjects:
Online Access:https://purl.fdlp.gov/GPO/gpo19964
Description
Summary:Operational requirements of the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor necessitate the implementation of fuel follower control rods (FFCR's). This technical report discusses the operational and safety aspects of FFCR installation. Thermal hydraulic analysis shows that FFCR's can be operated safely in the AFRRI TRIGA reactor. The maximum calculated fuel temperature at the maximum steady-state power level is well within the limit of the maximum safe operating temperature set by the Technical Specifications.
Item Description:Title from title screen (viewed on Mar. 12, 2012).
"May 1991"--Technical rept. documentation p.
Electronic resource.
Physical Description:1 online resource (iii, 17 pages) : illustrations
Bibliography:Includes bibliographical references (pages 9-10).