Inaccuracy of diagnostic equipment for motor-operated butterfly valves.
| Corporate Author: | U.S. Nuclear Regulatory Commission. Office of Nuclear Reactor Regulation |
|---|---|
| Format: | Government Document eBook |
| Language: | English |
| Published: |
Washington, D.C. :
U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation,
[1996]
|
| Series: | NRC information notice ;
96-30. |
| Subjects: | |
| Online Access: | https://purl.fdlp.gov/GPO/gpo1782 |
Similar Items
Vibration-induced degradation of butterfly valves.
Published: (2005)
Published: (2005)
Potential failure of motor-operated butterfly valves to operate because valve seat friction was underestimated.
Published: (1990)
Published: (1990)
Problem with Henry Pratt motor-operated butterfly valves.
Published: (1994)
Published: (1994)
Dependency of offset disc butterfly valve's operation on orientation with respect to flow.
Published: (1991)
Published: (1991)
Potential inadequacies in the prediction of torque requirement of and torque output for motor-operated butterfly valves.
Published: (1994)
Published: (1994)
Potential overstress of shafts on Fisher series 9200 butterfly valves with expandable T rings.
Published: (1981)
Published: (1981)
Failure of elastomer seated butterfly valves used only during cold shutdowns.
Published: (1984)
Published: (1984)
Preliminary results of validation testing of motor-operated valve diagnostic equipment.
Published: (1991)
Published: (1991)
Accuracy of motor-operated valve diagnostic equipment manufactured by Liberty Technologies.
Published: (1993)
Published: (1993)
Butterfly valves : torque, head loss, and cavitation analysis.
Published: (2001)
Published: (2001)
Recent NRC-sponsored testing of motor-operated valves.
Published: (1989)
Published: (1989)
Results of NRC-sponsored testing of motor-operated valves.
Published: (1990)
Published: (1990)
Accuracy of motor-operated valve diagnostic equipment (responses to supplement 5 to Generic Letter 89-10).
Published: (1994)
Published: (1994)
Motor-operated valve actuator thrust variations measured with a torque thrust cell and a strain gage.
Published: (1993)
Published: (1993)
Results of validation testing of motor-operated valve diagnosis equipment.
Published: (1992)
Published: (1992)
Inaccuracy of safety valve set pressure determinations using assist devices.
Published: (1994)
Published: (1994)
Crosby relief valve setpoint drift problems caused by corrosion of the guide ring.
Published: (1998)
Published: (1998)
Inadequacies in the design of DC motor-operated valves.
Published: (1988)
Published: (1988)
Inoperability of power-operated relief valves masked by downstream indications during testing.
Published: (1996)
Published: (1996)
Safety-related (1) motor-operated valve testing and surveillance results of the public workshops.
Published: (1989)
Published: (1989)
Potential design deficiency in motor-operated valve control circuitry.
Published: (2013)
Published: (2013)
Butterfly valves : torque, head loss, and cavitation analysis /
by: Bosserman, Bayard E., II
Published: (2012)
by: Bosserman, Bayard E., II
Published: (2012)
Motor-operated valve performance issues.
Published: (1996)
Published: (1996)
Vibration-induced valve failures.
Published: (1983)
Published: (1983)
Malfunction of a pressurized code safety valve.
Published: (1993)
Published: (1993)
Horizontally-installed motor-operated gate valves.
Published: (1992)
Published: (1992)
Failure of Limitorque motor-operated valves resulting from incorrect installation of pinion gear.
Published: (1985)
Published: (1985)
Inservice testing of pumps and valves, and inservice examination and testing of dynamic restraints (snubbers) at nuclear power plants : draft report for comment /
by: Tingen, S. G.
Published: (2010)
by: Tingen, S. G.
Published: (2010)
Periodic verification of design-basis capability of safety-related motor-operated valves.
Published: (1996)
Published: (1996)
Motor-operated valve failures due to hammering effect.
Published: (1985)
Published: (1985)
Effects of changing valve motor-operator switch settings.
Published: (1986)
Published: (1986)
Setpoint testing of pressurizer safety valves with filled loop seals using hydraulic assist devices.
Published: (1988)
Published: (1988)
Motor brakes on valve actuator motors.
Published: (1993)
Published: (1993)
Susceptibility of containment sump recirculation gate valves to pressure locking.
Published: (1995)
Published: (1995)
Failure of DC motor-operated valves to develop rated torque because of improper cable sizing.
Published: (1989)
Published: (1989)
Failures of motor-operated valves due to degraded stem lubricant.
Published: (2010)
Published: (2010)
Motor-operated valve inoperable due to stem-disc separation.
Published: (2012)
Published: (2012)
Failure of motor-operated valve electric power train due to sheared or dislodged motor pinion gear key.
Published: (1994)
Published: (1994)
Control valve capacity test procedure.
Published: (1988)
Published: (1988)
Check valve inservice testing program deficiencies.
Published: (1988)
Published: (1988)