Ambient aerosol sampling inlet for flow rates of 100 and 400 L/min /

Bibliographic Details
Main Author: Baehl, Michael Matthew
Other Authors: McFarland, Andrew R. (Thesis advisor)
Format: Thesis eBook
Language:English
Published: [College Station, Tex.] : [Texas A&M University], [2010]
Subjects:
Online Access:Link to OAK Trust copy
Description
Abstract:New bioaerosol sampling inlets were designed and tested that have nominal exhaust flow rates of 100 L/min to 400 L/min, and which have internal fractionators and screens to scalp large, unwanted particles and debris from the transmitted size distribution. These units consist of the same aspiration section, which is a 100 L/min Bell Shaped Inlet (BSI-100), and different pre-separators. The pre-separators are called the IRI-100 (Inline Real Impactor) with an exhaust flow rate of 100 L/min, the IRI-400 (exhaust flow rate of 400 L/min), the IVI-300 (Inline Virtual Impactor for a flow rate of 300 L/min) and the IVI-400. These units were tested in a wind tunnel at speeds of 2, 8, and 24 km/hr with particle sizes between 3 and 20 [mu]m AD (aerodynamic diameter). The units show wind independent characteristics over the range of wind speeds tested. The aspiration section of the BSI-100 has greater than 85% penetration for particle sizes [less than or equal to] 10 [mu]m AD. The IRI-100, IRI-400, IVI-300 and IVI-400, when combined with the BSI-100 all provide cutpoints of 11 ± 0.5 [mu]m AD.
Item Description:"Major Subject: Mechanical Engineering"
Title from author supplied metadata (automated record created 2010-08-20 08:31:34).
Electronic resource.
Physical Description:1 online resource.
Bibliography:Includes bibliographical references.