Experimental identification of structural force coefficients in a bump-type foil bearing /

Bibliographic Details
Main Author: Breedlove, Anthony Wayne
Other Authors: San Andres, Luis A. (Thesis advisor)
Format: Thesis eBook
Language:English
Published: [College Station, Tex.] : [Texas A&M University], [2010]
Subjects:
Online Access:Link to OAK Trust copy
Description
Abstract:This thesis presents further experimentation and modeling for bump-type gas foil bearings used in oil-free turbomachinery. The effect of shaft temperature on the measured structural force response of foil bearings is of importance for reliable high temperature applications. During actual operation with shaft rotation, the bearing structural parameters are coupled to the effects of a hydrodynamic gas film layer, thus determining the overall bearing load performance. A 38.17 mm inner diameter foil bearing, Generation II, is mounted on an affixed non-rotating hollow shaft with an outer diameter of 38.125 mm. A cartridge heater inserted into the shaft provides a controllable heat source. The clearance between the shaft and the foil bearing increases with increasing shaft temperatures (up to 188[degrees]C). A static load (ranging from 0 N to 133 N) is applied to the bearing housing, while measuring the resulting bearing displacement, which represents the compliant structure deflection. Static load versus displacement tests render the bearing static structural stiffness. As the shaft temperature increases, the static test results indicate that the bearing structural stiffness decreases by as much as 70% depending on the bearing orientation. A dynamic load test setup includes a rigid shaft support structure and a suspended electromagnetic shaker. Dynamic load (from 13 N to 31 N) test results show that the test foil bearing stiffness increases by as much as 50% with amplitude of dynamic load above a lightly loaded region, nearly doubles with frequency up to 200 Hz, and decreases by a third as shaft temperature increases. A stick slip phenomenon increases the bearing stiffness at higher frequencies for all the amplitudes of dynamic load tested. The test derived equivalent viscous damping is inversely proportional to amplitude of dynamic load, excitation frequency, and shaft temperature. Further, the estimated bearing dry friction coefficient decreases from 0.52 to 0.36 with amplitude of dynamic load and stays nearly constant as shaft temperature increases. Test results identify static and dynamic bearing parameters for increasing shaft temperature. These experimental results provide a benchmark for predictions from analytical models in current development and are essential to establish sound design practices of the compliant bearing structure.
Item Description:"Major Subject: Mechanical Engineering"
Title from author supplied metadata (automated record created 2010-03-12 12:08:51).
Electronic resource.
Physical Description:1 online resource.
Bibliography:Includes bibliographical references.