Cylindrical detector and preamplifier design for detecting neutrons /

Bibliographic Details
Main Author: Xia, Zhenghua
Format: Thesis eBook
Language:English
Published: [College Station, Tex.] : [Texas A&M University], [2010]
Subjects:
Online Access:Link to OAK Trust copy

MARC

Tag First Indicator Second Indicator Subfields
LEADER 00000cam a2200000Ka 4500
001 in00002575448
005 20151201150145.0
006 m f d
007 cr unu||||||||
008 100428s2010 txu sbm 000 0 eng d
035 |a (OCoLC)ocn609898317 
035 |a (OCoLC)609898317 
035 |a (TxCM)http://hdl.handle.net/1969.1/ETD-TAMU-2008-12-158 
040 |a TXA  |c TXA  |d UtOrBLW 
049 |a TXAM 
099 |a 2008  |a Dissertation  |a 1969.1/ETD-TAMU-2008-12-158 
100 1 |a Xia, Zhenghua. 
245 1 0 |a Cylindrical detector and preamplifier design for detecting neutrons /  |c by Zhenghua Xia. 
264 1 |a [College Station, Tex.] :  |b [Texas A&M University],  |c [2010] 
300 |a 1 online resource. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
500 |a "Major Subject: Nuclear Engineering" 
500 |a Title from author supplied metadata (automated record created 2010-03-12 12:08:51). 
502 |b Doctor of Philosophy  |c Texas A&M University  |d 2008  |o http://hdl.handle.net/1969.1/ETD-TAMU-2008-12-158 
504 |a Includes bibliographical references. 
516 |a Text (Dissertation) 
520 3 |a Tissue equivalent proportional counters are frequently used to measure dose and dose equivalent in mixed radiation fields that include neutrons; however, detectors simulating sites 1?m in diameter underestimate the quality factor, Q, for low energy neutrons because the recoil protons do not cross the detectors. Proportional counters simulating different site-sizes can be used to get a better neutron dose equivalent measurement since the range and stopping power of protons generated by neutrons in the tissue-equivalent walls depend on the energy of the primary neutrons. The differences in the spectra measured by different size detectors will provide additional information on the incident neutron energy. Monte Carlo N-particle extended (MCNPX) code was used to simulate neutron transportation in proportional counters of different simulated tissue diameter. These Monte Carlo results were tested using two solid walled tissue equivalent proportional counters, 2mm and 10mm in diameter, simulating tissue volumes 0.1'm and 0.5'm in diameter, housed in a single vacuum chamber. Both detectors are built with 3mm thick tissue equivalent plastic (A-150) walls and propane gas inside for dose measurement. Using these two detectors, the spectra were compared to determine the underestimation of y for large detector, and thereby obtain more information of the incident neutron particles. Based on the MCNPX simulation and experimental results, we can see that the smaller detector produces a larger average lineal energy than the larger detector, which means the larger detector (0.5?m diameter tissue equivalent size) underestimates the Q value for the low energy neutron, therefore underestimates the effective dose. These results confirm the results of the typical analysis of lineal energy as a function of site size. 
500 |a Electronic resource. 
650 4 |a Major nuclear engineering. 
653 |a Site Size 
653 |a MCNPX 
653 |a Tissue Equivalent Proportional Counters 
653 |a Neutron 
856 4 0 |u http://hdl.handle.net/1969.1/ETD-TAMU-2008-12-158  |z Link to OAK Trust copy  |t 0 
948 |a cataloged  |b h  |c 2010/4/28  |d c  |e jgreene  |f @:45:45 pm 
994 |a C0  |b TXA 
999 |a MARS 
999 f f |s 52d0c9bb-ce45-36e6-b240-37159547c5cb  |i 092ba29c-81cc-36f8-ac3f-b474f68e651b  |t 0 
952 f f |a Texas A&M University  |b College Station  |c Electronic Resources  |s www_evans  |d Available Online  |t 0  |e 2008 Dissertation 1969.1/ETD-TAMU-2008-12-158  |h Other scheme 
998 f f |a 2008 Dissertation 1969.1/ETD-TAMU-2008-12-158  |t 0  |l Available Online