Parameterization of the size and shape of intracranial saccular aneurysms using Legendre polynomials /

Bibliographic Details
Main Author: Farley, Cory Wayne, 1976-
Other Authors: Humphrey, Jay D. (Thesis advisor)
Format: Thesis eBook
Language:English
Published: [College Station, Tex.] : [Texas A&M University], [2005]
Subjects:
Online Access:Link to OAK Trust copy
Description
Abstract:Currently, size is used as the predetermining factor to judge whether a saccular aneurysm is likely to rupture. Recent studies of the nonlinear mechanics of saccular aneurysms suggest that it is unlikely that they enlarge or rupture via material (limit point) or dynamic (resonance) instabilities. Rather, there is a growing body of evidence from both vascular biology and finite element analyses that implicate mechanosensitive growth and remodeling processes. There is, therefore, an even greater need to quantify regional multiaxial wall stresses, which because of the membrane-like behavior of aneurysms implicates the need for better data on regional surface curvatures. By using a convenient function, such as a Legendre polynomial, a quick, accurate approximation can be made for the size and shape of a saccular aneurysm that allows for stress analysis that surgeons can use to determine if the risk of rupture warrants the risk of treatment.
Item Description:"Major Subject: Biomedical Engineering"
Title from author supplied metadata (automated record created on Feb. 17, 2005.)
Vita.
Abstract.
Electronic resource.
Format:Mode of access: World Wide Web.
System requirements: World Wide Web access and Adobe Acrobat Reader.
Bibliography:Includes bibliographical references.