An analysis of shaft/shaft seal interaction of a multiple disk centrifugal blood pump /

A multiple disk centrifugal blood pump is in the early stages

Bibliographic Details
Main Author: Manning, Keefe Baird, 1973-
Format: Thesis eBook
Language:English
Published: [Place of publication not identified] : [publisher not identified] ; 1997.
Subjects:
Online Access:Link to OAKTrust copy

MARC

Tag First Indicator Second Indicator Subfields
LEADER 00000ctm a22000005a 4500
001 in00001379708
005 20220103134710.0
007 cr unu a
008 971015s1997 xx a b 000 0 eng d
035 |9 AHL4241AM 
035 |a (OCoLC)37787906 
040 |a TXA  |c TXA  |d UtOrBLW 
049 |a TXAM  |a TXAR 
099 |a 1997  |a Thesis  |a M36 
100 1 |a Manning, Keefe Baird,  |d 1973- 
245 1 3 |a An analysis of shaft/shaft seal interaction of a multiple disk centrifugal blood pump /  |c by Keefe Baird Manning. 
264 1 |a [Place of publication not identified] :  |b [publisher not identified] ;  |c 1997. 
300 |a x, 177 leaves :  |b illustrations ;  |c 28 cm. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
500 |a "Major subject: Bioengineering". 
500 |a Vita. 
502 |b M.S.  |c Texas A&M University  |d 1997. 
504 |a Includes bibliographical references: pages 51-54. 
520 |a A multiple disk centrifugal blood pump is in the early stages  
520 |a adverse circumstances, materials and shafts are being  
520 |a adverse effects for the patient. Because of these possibly  
520 |a diameters (0.5" and 0.75"). The three main parameters  
520 |a diameters along with the inner and outer temperatures. The  
520 |a durations (I 5, 3 0, 4 5, and 60 minutes), four rotation  
520 |a during or after implantation, potential events such as blood  
520 |a evaluated to determine the most appropriate course to limit  
520 |a evaluated were the inner diameter, the inner temperature, and  
520 |a for the shaft seal materials, the shafts, and the outer  
520 |a information to suggest the need for either in vitro testing  
520 |a interface are of major interest. If leakage were to occur  
520 |a loss, clotting, blood damage, and/or infections could produce  
520 |a Melonite 9 coated shaft, the latter provided by Houston  
520 |a notable was that the coated shaft did not significantly  
520 |a of development. As is the case with most pumps that are  
520 |a of the shaft seal or examining alternatives such as magnetic  
520 |a on wear. Some unexpected information was produced. Most  
520 |a rates (800, 1000, 1200, and 1400 RPM), and two outer  
520 |a reduce the amount of wear. This testing has provided enough  
520 |a results indicated that time and RPM had no significant effect  
520 |a shaft driven, leakage problems around the shaft/shaft seal  
520 |a shaft seal candidates with both a stainless steel shaft and a  
520 |a suspension or ferrofluidic sealing. 
520 |a The materials and shafts were evaluated under four time  
520 |a the outer temperature. Statistical comparisons were computed  
520 |a these effects. Teflon and Nylon were analyzed as potential  
520 |a Unlimited Inc. Metal Processing in Chappell Hill, Texas.  
530 |a Also available online. 
530 |a Issued also on microfiche from Lange Micrographics. 
650 4 |a Major bioengineering. 
856 4 1 |u https://hdl.handle.net/1969.1/ETD-TAMU-1997-THESIS-M36  |z Link to OAKTrust copy  |t 0 
999 |a MARS 
999 f f |s a2ebd386-c4b4-3782-ace0-77f19052514b  |i e49ae17a-1e94-30e2-bc63-da72181bcb1e  |t 0 
952 f f |p noncirc  |a Texas A&M University  |b College Station  |c Cushing Memorial Library & Archives  |s cush tdrm  |d Cushing: Theses & Dissertations Microforms (Does not check out)  |t 0  |e 1997 Thesis M36  |h Other scheme  |i computer -- online resource 
952 f f |a Texas A&M University  |b College Station  |c Electronic Resources  |s www_evans  |d Available Online  |t 0  |e 1997 Thesis M36  |h Other scheme 
998 f f |a 1997 Thesis M36  |t 0  |l Cushing: Theses & Dissertations Microforms (Does not check out) 
998 f f |a 1997 Thesis M36  |t 0  |l Available Online