Radiological engineering evaluation of the delay line air scrubber located at the Clinton P. Anderson Meson Physics Facility (LAMPF) /

addition of an air scrubber to an already existing delay line

Bibliographic Details
Main Author: Huneycutt, Scott Edward
Format: Thesis eBook
Language:English
Published: [Place of publication not identified] : [publisher not identified] ; 1996.
Subjects:
Online Access:Link to OAKTrust copy
Description
Summary:addition of an air scrubber to an already existing delay line
and compared those values with measurements from radiological
and the efficiency of 11CO2 removal was determined to be
and whether it would scrub 11CO2. There were three main
around 50%. Microshield was then used to predict dose rates
blocks around the scruber were effective in reducing the dose
determine the scrubbing efficiency of the scrubber. The
in the scrubber area and compare those values with
in the scrubber.
information was used to calculate the scrubbing efficiency
measurements from radiological surveys. The third objective
objectives of this study. The first objective was to
rates from the radiation field produced by the radionuclides
reducing the dose rates in the scrubber area. The activities
scrubbing efficiency was then used to predict the dose rates
surveys. This was also used to determine the that the shield
The purpose of this study was to determine the effects of the
was to determine if the shield blocks were effective in
were measured before and during scrubber operation and this
Item Description:"Major subject: Health Physics".
Vita.
Physical Description:x, 160 leaves : illustrations ; 28 cm.
Also available online.
Issued also on microfiche from Lange Micrographics.
Bibliography:Includes bibliographical references.