The measurement and analysis of the magnetic field of a synchrotron light source magnet /

An exact equation is found for the measured "center line"

Bibliographic Details
Main Author: Graf, Udo Werner, 1965-
Format: Thesis eBook
Language:English
Published: [Place of publication not identified] : [publisher not identified] ; 1994.
Subjects:
Online Access:Link to OAKTrust copy
Description
Summary:An exact equation is found for the measured "center line"
data. The accuracy of the measuring system is determined by
designed to produce a magnetic field up to 3 Tesla in
experimental errors.
extending from each end of the cylinder. The magnet operates
field values along the center line of the magnet are mapped.
In this thesis a unique system is used to measure the
Inferences are made about the nature of all observed I
inside of a vacuum chamber, at a temperature of 4.2 degrees
Kelvin. The radial profile of the magnetic field and the
magnet. The magnet measured is a superferric dipole C-magnet
magnetic field of a superconducting synchrotron light source
magnitude. Its geometry is that of a curved cylinder
performing statistical analysis on the measured data.
spanning an angle of 90 degrees, with straight sections
Item Description:"Major subject: Physics".
Vita.
Physical Description:vii, 55 leaves : illustrations ; 28 cm.
Also available online.
Bibliography:Includes bibliographical references.