A continuously weighed pycnometer providing densities for carbon dioxide+ethane mixtures between 240 and 350 K at pressures up to 35 MPa / by /

Bibliographic Details
Main Author: Lau, Wing-Wah Robbie, 1956-
Other Authors: Eubank, P. T. (degree committee member.), McDermott, Make (degree committee member.)
Format: Thesis Book
Language:English
Published: 1986.
Subjects:
Online Access:Link to ProQuest copy
Link to OAKTrust copy

MARC

Tag First Indicator Second Indicator Subfields
LEADER 00000ctm a2200000Ia 4500
001 in00000018047
005 20220104090741.0
008 880613s1986 xx a bm 000 0 eng d
035 |9 AAB0529AM 
035 |a (OCoLC)18077521 
035 |a (OCoLC)ocm18077521 
040 |a TXA  |b eng  |c TXA  |d OCLCQ  |d OCLCO  |d TXA 
049 |a TXAM 
099 |a 1986  |a Disser-  |a tation  |a L366 
100 1 |a Lau, Wing-Wah Robbie,  |d 1956- 
245 1 2 |a A continuously weighed pycnometer providing densities for carbon dioxide+ethane mixtures between 240 and 350 K at pressures up to 35 MPa / by / 
264 1 |c 1986. 
300 |a ix, 114 leaves :  |b illustrations ;  |c 29 cm 
336 |a text  |b txt  |2 rdacontent 
337 |a unmediated  |b n  |2 rdamedia 
338 |a volume  |b nc  |2 rdacarrier 
500 |a "Major subject: Chemical Engineering." 
500 |a Typescript (photocopy). 
500 |a Vita. 
502 |b Ph. D.  |c Texas A & M University  |d 1986 
504 |a Includes bibliographical references (leaves 79-82). 
520 3 |a A new, continuously weighed pycnometer has been constructed for fast and accurate density measurements. This apparatus consists of a sample cell that is suspended from an electronic balance at all times. The sample cell is filled and evacuated through a flexible capillary that remains attached to the sample cell without affecting the precision of the balance. Data collection occurs at a rate of one measurement every twenty minutes along an isotherm. The precision of liquid density measurement is 0.2 kg/m^3, and the accuracy has been shown to be better than 0.1%. With this apparatus, we have measured densities of pure carbon dioxide, ethane, and four of their mixtures at six temperatures between 240 and 350 K, and at pressures up to 35 MPa. Measurements outside these ranges are currently limited by the pressure transducer inside the isothermal bath. With a suitable pressure measurement device, this apparatus can be used for density measurements between 200 and 500 K and at pressures up to 170 MPa. 
650 0 |a Carbon dioxide  |x Density. 
650 0 |a Ethanes  |x Density. 
650 0 |a Pycnometer  |x Design and construction. 
650 0 |a Specific gravity  |x Measurement. 
650 4 |a Major chemical engineering. 
655 7 |a Academic theses  |2 lcgft 
700 1 |a Eubank, P. T.,  |e degree committee member. 
700 1 |a Hall, K. R.,  |e degree supervisor. 
700 1 |a Holste, James C.,  |e degree supervisor. 
700 1 |a McDermott, Make,  |e degree committee member. 
710 2 |a Texas A & M University,  |e degree granting institution. 
856 4 1 |u http://proxy.library.tamu.edu/login?url=http://proquest.umi.com/pqdweb?did=752633271&sid=1&Fmt=2&clientId=2945&RQT=309&VName=PQD  |z Link to ProQuest copy  |t 0 
856 4 1 |u https://hdl.handle.net/1969.1/DISSERTATIONS-24184  |z Link to OAKTrust copy  |t 0 
994 |a C0  |b TXA 
999 f f |s cf79076f-537d-39b0-8c70-849867765ddd  |i 72c01b6d-1dae-3169-95af-cae8c6c5fd75  |t 0 
952 f f |p noncirc  |a Texas A&M University  |b J.J. Pickle Campus  |c High Density Repository  |s HDR  |d Remote Storage  |t 0  |e 1986 Dissertation L366  |h Other scheme  |i unmediated -- volume  |m A14839614574 
952 f f |a Texas A&M University  |b College Station  |c Electronic Resources  |s www_evans  |d Available Online  |t 0  |e 1986 Dissertation L366  |h Other scheme 
998 f f |a 1986 Dissertation L366  |t 0  |l Available Online 
998 f f |a 1986 Dissertation L366  |t 0  |l Remote Storage